To continuously increase the administration process by virtue of the rule of "sincerely, good religion and excellent are the base of company development", we commonly absorb the essence of linked goods internationally, and continually build new solutions to fulfill the requires of shoppers for
100kvatransformer,
Manufacturer Of Transformers,
Medium Voltage Circuit Breaker, Now we have experienced manufacturing facilities with extra than 100 employees. So we could guarantee short lead time and high quality assurance.
Power Line Fittings Quotes – Power Distribution Equipment Rated Mechanical Bending Load 11KV 12KV 12.5KV Suspension composite insulator – JSM TRANSFORMER Detail:
Features:
1. The product adopts epoxy resin material. It gains high level of insulation, intensity and stability.
2. Bushing series is used for insulation and connection transition of completes with rated voltage of 12KV, 40.5KV and below.
3. Epoxy resin vacuum casting, the APG epoxy resin pressure gelatin, the liquid silica gel formation, we always supplies the best quality products.
4. It can be detected by X-ray instrument, bureau put instrument, thermal Cycle Test Machine.
5 .It provides different specifications based on the size of electric current for the user’s choice, and sold well both at home and abroad.
Applicable Work Environment:
- Indoor installation. 2. Altitude: ≤1000m. 3. Ambient temperature: -10°C~+40°C. 4. Creepage distance: ≥20mm/KV 5. The relative humidity shall not be more than 85%at+20°C ambient temperature. 6. NO gas, vapor or dust that may severely affect the insulation of contact box, no explosive or corrosive substance
Application
The primary purpose of any Cut-out Fuse is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks.
Cutout fuse provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.

Technical Data:
| Type: |
Rated Voltage |
Rated Current |
Beaking Current |
Impulse Voltage |
Power-frequency
withstand voltage |
Leakage
distance |
| kV |
A |
BIL |
kV |
mm |
kg |
| SM-1 |
12 |
100 |
6.3 |
110 |
40 |
250 |
| SM-1 |
12 |
200 |
8 |
110 |
40 |
250 |
| SM-2 |
15 |
100 |
10 |
125 |
45 |
320 |
| SM-2 |
15 |
200 |
12 |
125 |
45 |
320 |
| SM-3 |
24 |
100 |
8 |
150 |
65 |
530 |
| SM-3 |
24 |
200 |
10 |
150 |
65 |
530 |
| SM-4 |
15 |
100 |
10 |
125 |
45 |
350 |
| SM-4 |
15 |
200 |
12 |
125 |
45 |
350 |
| SM-5 |
12 |
100 |
6.3 |
110 |
40 |
250 |
| SM-5 |
12 |
200 |
8 |
110 |
40 |
250 |
| SM-6 |
15 |
100 |
10 |
125 |
45 |
320 |
| SM-6 |
15 |
200 |
12 |
125 |
45 |
320 |
| SM-7 |
24 |
100 |
8 |
150 |
65 |
540 |
| SM-7 |
24 |
200 |
10 |
150 |
65 |
540 |
| SM-7(F) |
33 |
200 |
12 |
170 |
70 |
720 |
| SM-8 |
33 |
100 |
10 |
170 |
70 |
720 |
| SM-8 |
33 |
200 |
12 |
170 |
70 |
720 |
Product detail pictures:
Related Product Guide:
Our rewards are lower costs,dynamic profits team,specialised QC,potent factories,high-quality services for Power Line Fittings Quotes – Power Distribution Equipment Rated Mechanical Bending Load 11KV 12KV 12.5KV Suspension composite insulator – JSM TRANSFORMER , The product will supply to all over the world, such as: Slovak Republic, Thailand, Czech, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information if you have any questions. We are glad to work for every client.